1 |
使用温度范围
Operating temperature range |
-40℃ ~ +85℃ |
-25℃ ~ +85℃ |
2 |
额定电压范围(UR)
Rated working voltage range |
6.3~100V |
160~500V |
4 |
静电容量允许偏差
Capacitance tolerance |
-10~+30%,±20% |
5 |
损耗角正切值 (tgδ)
Tangent of the loss angle
20℃,100Hz/120Hz |
UR(V) |
25~100 |
160 |
200 |
250 |
350 |
400 |
450 |
tgδ |
见后表 |
0.15 |
0.20 |
|
6 |
漏电流(μA , 2min)
Leakage current |
I≤0.01CRUR或5mA取小者。
I≤0.01CRUR or 5mA whichever is smaller. |
8 |
耐久性(105℃)
Load life |
105℃施加额定电压3000小时后 |
漏电流:
损耗角正切值tgδ:
静电容量变化率: |
≤规定值
≤规定值的200%
≤±15% |
After rated voltage is applied for 3000 hours at 105℃ |
Leakage current :
tgδ:
Percentage of capacitance change : |
≤initial specified value
≤200% of specified value
≤±15% of initial value |
9 |
高温贮存(105℃)
Shelf life |
105℃放置1000小时 |
漏电流:
损耗角正切值tgδ:
静电容量变化率: |
≤规定值的200%
≤规定值的150%
≤±20% |
Test time: 1000hours at 105℃ |
Leakage current :
tgδ:
Percentage of capacitance change : |
≤200% of specified value
≤150% of specified value
≤±20% of initial value |
|
|
|
|
|